Full Gauge
Periodical defrost may be performed with MT-512E-2HP by stopping the compressor (natural defrost) and forcing defrost manually. It is provided with a powerful 16A relay for actuating loads of up to 2HP, in addition to a command output combined with a timer for programming refrigeration and defrosting times. Another feature available is the turning off of the control functions, making the MT-512E-2HP operate only as a temperature indicator. It is also provided with a configurable digital filter, which has the purpose of simulating mass increase in the environment sensor, thus increasing its response time, i.e., it renders the sensor response slower (delay). Through an intelligent function blocking system, it prevents unauthorized personnel from changing the control parameters. MT-512E-2HP can also be set for heating.
Full Gauge
For frozen goods, the TC-900E-Log automates the defrosting process according to the needs of the facility (intelligent defrosting), providing energy savings. It operates with two sensors, one for room temperature and the other, fastened to the evaporator, that controls defrosting completion and fan restarting. The room temperature control has a normal setpoint and an economy setpoint, in addition to the fast freezing functionality and alarm functions indicating that the door is open. It features up to two digital inputs. One of these inputs may be configured as sensor 3* to monitor the condenser temperature and disconnect the control outputs in case of an alarm. It also features a digital filter, which is intended to simulate an increase of the mass of the room temperature sensor (S1), thus increasing its response time (thermal inertia), and avoiding unnecessary compressor activation. Its 16-Amp relay output can control compressors of up to 1 hp and the defrost output has a current capacity of 10 Amp.
TC-900E-Log contain an hourmeter to count the operating hours of the compressor, and an internal real time clock that enables the creation of a defrost schedule for each day of the week. Besides, with the help of an internal auxiliary power supply, the clock keeps working even in case of a power fault for at least 72 hours.
Full Gauge
For frozen goods, the TC-900E-Log automates the defrosting process according to the needs of the facility (intelligent defrosting), providing energy savings. It operates with two sensors, one for room temperature and the other, fastened to the evaporator, that controls defrosting completion and fan restarting. The room temperature control has a normal setpoint and an economy setpoint, in addition to the fast freezing functionality and alarm functions indicating that the door is open. It features up to two digital inputs. One of these inputs may be configured as sensor 3* to monitor the condenser temperature and disconnect the control outputs in case of an alarm. It also features a digital filter, which is intended to simulate an increase of the mass of the room temperature sensor (S1), thus increasing its response time (thermal inertia), and avoiding unnecessary compressor activation. Its 16-Amp relay output can control compressors of up to 1 hp and the defrost output has a current capacity of 10 Amp.
TC-900E-Log contain an hourmeter to count the operating hours of the compressor, and an internal real time clock that enables the creation of a defrost schedule for each day of the week. Besides, with the help of an internal auxiliary power supply, the clock keeps working even in case of a power fault for at least 72 hours.